0437 Film Drive Feedback Fault

"Failure of the feedback device. The feedback device has detected an internal error. The nn sub-code is defined as follows:

1: ACCELERATION OVERFLOW

4: TRACKING FILTER ERROR

5: VECTOR LENGTH ERROR

6: COUNTER ERROR

7: SYNCHRONIZATION ERROR"

  • Check motor feedback cable and connector.
  • Switch off the control voltage and switch it back on again.
  • Replace motor if the fault persists.
  • Check feedback shield connection.
  • Reduce shock and vibration to motor.

Failure of the feedback device. The feedback device has detected an internal error. The nn sub-code is defined as follows:

16: SINGLE TURN ERROR

17: MULTI TURN AMPLITUDE ERROR

18: MULTI TURN SYNC ERROR

19: MULTI TURN VECTOR LENGTH ERROR

  • Check motor feedback cable and connector.
  • Switch off the control voltage and switch it back on again.
  • Replace motor if the fault persists.
  • Check feedback shield connection.
  • Reduce shock and vibration to motor.

Failure of the feedback device. The feedback device has detected an internal error. The nn sub-code is defined as follows:

35: STANDARD PARAMETER ERROR

36: INTERNAL COMMUNICATION ERROR

137: INTERNAL COMMUNICATION ERROR

238: INTERNAL SYSTEM ERROR

  • Check motor feedback cable and connector.
  • Switch off the control voltage and switch it back on again.
  • Replace motor if the fault persists.
  • Check feedback shield connection.
  • Reduce shock and vibration to motor.

Failure of the feedback device. The feedback device has detected an internal error. The nn sub-code is defined as follows:

48: CRITICAL TEMPERATURE

49: CRITICAL LED CURRENT

50: CRITICAL SUPPLY VOLTAGE

51: CRITICAL SPEED

  • Check motor feedback cable and connector.
  • Switch off the control voltage and switch it back on again.
  • Replace motor if the fault persists.
  • Check feedback shield connection.
  • Reduce shock and vibration to motor.

Failure of the feedback device. The feedback device has detected an internal error. The nn sub-code is defined as follows:

52: CRITICAL ACCELERATION

53: COUNTER OVERFLOW

54: INTERNAL MONITORING ERROR

66: INTERNAL RESOURCE ACCESS ERROR

  • Check motor feedback cable and connector.
  • Switch off the control voltage and switch it back on again.
  • Replace motor if the fault persists.
  • Check feedback shield connection.
  • Reduce shock and vibration to motor.

------------------------------------------------------------------------

More Rovema Support Options

See Additional Error Codes

Submit a Support Ticket

Looking for a manual for your Vertical Form Fill and Seal (VFFS) Bagger? Click here!

 