Unsatisfactory Bag Seam Resistance
Faults forming the cross seam
• Set the sealing temperature and pressure setting according to the jaw pressure measurement results (for hot sealing).
• Set the pulse duration/strength and welding pressure according to the jaw pressure measurement results (for pulse welding). The cross seams are fully closed on empty bags, but open on filled ones.
------------------------------------------------------------------------