0230 Temperature Too Low, Front Jaw

Temperature Too Low, Front Jaw

The tolerance range of the reported zone was under ranged.

a) The machine was switched on recently and the temperature zone is currently being heated up.

b) The setpoint temperature was raised and the temperature is currently being heated up.

Wait for a moment and check the actual temperature display of the reported zone.

Increase the temperature tolerance in the temperature menu of the reported zone.

Change the control parameters in the configuration menu of the reported zone.

------------------------------------------------------------------------

More Rovema Support Options

See Additional Error Codes

Submit a Support Ticket

Looking for a manual for your Vertical Form Fill and Seal (VFFS) Bagger? Click here!

Manual CTA-1