0552 Temperature Too Low Right Vertical Jaw

The tolerance range of the reported zone was under ranged.

a) The machine was switched on recently and the temperature zone is currently being heated up.
b) The setpoint temperature was raised and the temperature is currently being heated up.

c) The temperature tolerance of the reported zone was set too low.
d) The temperature has dropped below the tolerance range when the machine stopped.

 

Wait for a moment and check the actual temperature display of the reported zone.

Increase the temperature tolerance in the temperature menu of the reported zone.

Change the control parameters in the configuration menu of the reported zone.

------------------------------------------------------------------------