Auger Feeder Drive Overtemp
The measured inverter temperature has exceeded the factory set temperature limit.
- Reduce the start-up times of all drives that share the DC bus.
- Reduce number of shared DC follower drives.
- Reduce the speed or extend the time in the command profile.
- Reduce drive ambient temperature.
- Ensure that that the air circulation in the drive is not obstructed.
Inverter overtemperature. Factory-set limit value exceeded. The measured inverter temperature has exceeded the factory set temperature limit.
- Reduce the speed or extend the time in the command profile.
- Reduce drive ambient temperature.
- Ensure that that the air circulation in the drive is not obstructed. Inverter overtemperature. Factory-set limit value exceeded.
------------------------------------------------------------------------