0417 Film Drive Thermal Overload

Film Drive Thermal Overload

Thermal overload of the inverter. Factory-set limit value exceeded. The thermal model for the power transistors indicates that the temperature has exceeded the factory set thermal capacity value of 110%.

•Reduce the speed or extend the time in the command profile. Thermal overload of the inverter. User limit value exceeded.

The thermal model for the power transistors indicates that the temperature has exceeded the user-defined limit value for the thermal overload of the inverter.

•Reduce the speed or extend the time in the command profile.

•Increase the inverter thermal overload attribute value. Thermal overload of the inverter. Factory-set limit value exceeded.

The converter thermal model indicates that the temperature has exceeded the factory set thermal capacity value of 110%.

•Reduce the start-up times of all drives that share the DC bus.

•Reduce number of shared DC follower drives.

•Reduce duty-cycle of the command axis control. Thermal overload of the inverter. User limit value exceeded.

•Reduce the start-up times of all drives that share the DC bus.

•Reduce number of shared DC follower drives.

•Reduce duty-cycle of the command axis control.

•Increase the inverter thermal overload attribute value.

Thermal overload of the bus regulator. Factory-set limit value exceeded. The thermal brake model has exceeded its factory set thermal capacity limit.

•Modify the duty cycle of the application.

•Add an external brake for additional capacity.

•Add a capacitor module if needed.

Thermal overload of the bus regulator. User limit value exceeded. The thermal brake model has exceeded the thermal capacity limit of the user- defined limit value for the thermal overload of the bus regulator.

•Modify the duty cycle of the application.

•Add an external brake for additional capacity.

•Increase the attribute value of the user-defined limit value for the thermal overload.

•Add a capacitor module if needed.

------------------------------------------------------------------------

More Rovema Support Options

See Additional Error Codes

Submit a Support Ticket

Looking for a manual for your Vertical Form Fill and Seal (VFFS) Bagger? Click here!

Manual CTA-1