0414 Sealing Jaw Drive Vertical Under torque Limit Fault
Undertorque limit fault. Motor torque has dropped below user defined mini-mum torque level given by undertorque limit for the duration of the undertorque limit time.
Check the motion profile.
Check the dimensioning of the drive and motor.
Decrease under torque limit and/or under torque limit time attribute values.
------------------------------------------------------------------------