0433 Film Drive Overtemp

Film Drive Overtemp

Inverter overtemperature. Factory-set limit value exceeded. The measured inverter temperature has exceeded the factory set temperature limit.

  • Reduce the speed or extend the time in he command profile.
  • Reduce drive ambient temperature.
  • Ensure that that the air circulation in the drive is not obstructed. Inverter overtemperature. Factory-set limit value exceeded.

The measured inverter temperature has exceeded the factory set temperature limit.

  • Reduce the start-up times of all drives that share the DC bus.
  • Reduce number of shared DC follower drives.
  • Reduce the speed or extend the time in the command profile.
  • Reduce drive ambient temperature.
  • Ensure that that the air circulation in the drive is not obstructed.

------------------------------------------------------------------------

More Rovema Support Options

See Additional Error Codes

Submit a Support Ticket

Looking for a manual for your Vertical Form Fill and Seal (VFFS) Bagger? Click here!

 

Manual CTA-1