0401 Sealing Jaw Drive Vertical Drive Overtemp

Inverter overtemperature. Factory-set limit value exceeded. The measured inverter temperature has exceeded the factory set temperature limit.

Reduce the speed or extend the time in the command profile.

Reduce drive ambient temperature.

Ensure that that the air circulation in the drive is not obstructed.

Reduce the start-up times of all drives that share the DC bus.

Reduce number of shared DC follower drives.

Reduce the speed or extend the time in the command profile.

Reduce drive ambient temperature.

Ensure that that the air circulation in the drive is not obstructed.

------------------------------------------------------------------------

More Rovema Support Options

See Additional Error Codes

Submit a Support Ticket

Looking for a manual for your Vertical Form Fill and Seal (VFFS) Bagger? Click here!

 

Manual CTA-1